Search filter

302 results found

Tender text IQ box Safety
Tender texts

Tender text IQ box Safety

DOCUMENT | 73 KB
Tender text TS 5000 L with guide rail BG 550
Tender texts

Tender text TS 5000 L with guide rail BG 550

DOCUMENT | 33 KB
Tender text Powerchain mit IQ box Safety
Tender texts

Tender text Powerchain mit IQ box Safety

DOCUMENT | 69 KB
Tender text Slimchain mit IQ box Safety
Tender texts

Tender text Slimchain mit IQ box Safety

DOCUMENT | 68 KB
Tender text GEZE Boxer E Closing force EN 2-4
Tender texts

Tender text GEZE Boxer E Closing force EN 2-4

DOCUMENT | 50 KB
Tender text GEZE Boxer EFS Closing force EN 4-6
Tender texts

Tender text GEZE Boxer EFS Closing force EN 4-6

DOCUMENT | 50 KB
Tender text OL 90 N for inward opening round or segmental arch window
Tender texts

Tender text OL 90 N for inward opening round or segmental arch window

DOCUMENT | 37 KB
FA GC 170 wireless extension
Flyer/folder

FA GC 170 wireless extension

tender texts, architects catalogues, and specialist information where necessary. Contact us at: Telephone: +49 7152 203-112 Monday – Friday: 7.30am – 5pm geze.com For more information regarding GEZE wireless extensions, please visit our homepage: www.geze.com/wireless This brochure was brought to you by: GEZE GmbH Reinhold-Vöster-Strasse 21–29 71229 Leonberg Germany Telephone: +49 7152 203-0 Fax: +49 7152 203-310 Email: info.de@geze.com

PDF | 583 KB
General terms and conditions for deliveries and services of GEZE GmbH
T&C / Data Protection

General terms and conditions for deliveries and services of GEZE GmbH

Text form is sufficient for notification of problems according to Section … (1) VOB/B (Construction Tendering and Contract Regulations B) or concerns according to Section … metres and approved by authorized persons before use. The contractual partner is obligated to notify the implementing installation company of the approval in text form. 6. Retention of title

PDF | 130 KB
Integrated door closers
Product brochure

Integrated door closers

SWING DOOR Integrated door closers INTEGRATED DOOR CLOSERS Contents Overview 04 FOR S IN GLE LE A F D O O R S Boxer 08 Boxer E with electric hold-open device 14 Boxer P for double-action doors 18 FOR S IN GLE LE A F D O O R S W I T H F R E E S W I N G FUN CTI O N Boxer EFS 24 FOR D OU B LE LE A F D O O R S Boxer ISM with integrated closing sequence control 30 Boxer E-ISM with electric hold-open device 38 FOR D OU B LE LE A F D O O R S W I T H F R E E S W I N G FUN CTI O N Boxer ISM-EFS with electric free swing function on the active leaf 48 BOX E R P IVOT B E A R I N G Integrated pivot bearing for opening restriction or holding open doors without a door closer 56 AC C ES S OR IES RSZ … smoke switch control unit 62 FU RTHE R IN FO R M AT I O N Product information for door closers 66 … 4 Integrated door closers | For single leaf doors | Overview OVERV IE W TA B LE O F I N T EG R AT E D D O O R CLO SER S For single leaf doors Boxer size 2-4 / 2-4 … V Boxer size 3-6 Boxer E size 2-4 Boxer E size 3-6 Boxer EFS Boxer P ● ● ● ● ● ● Barrier-free in accordance with DIN 18040 up to leaf width (max.) in mm EN4 1100 EN4 1100 FSA FSA FSA FL EN4 1100 Closing force acc. to EN 1154 2-4 3-6 2-4 3-6 4-6 2-4 Door leaf width (max.) in mm 1100 1400 1100 1400 1400 1100 Leaf weight (max.) in kg 130 180 130 180 180 80 Closer body integrated in the door leaf ● ● ● ● ● ● Guide rail integrated in the door frame ● ● ● ● ● ● 120° 120° 120° 120° 120° 120° Closing force, adjustable ● ● ● ● ● ● Back check, adjustable ● ● ● ● ● ● Latching action, adjustable ● ● ● ● ● ● Closing speed, adjustable ● ● ● ● ● ● Mechanical hold-open device² ● ● ● ● Approval for fire and smoke protection doors1 POSSIBLE APPLICATIONS Opening angle (max.) FUNCTIONS Electric hold-open device ● Electric hold-open device for free swing ● Mechanical closing sequence control, integrated Flexible opening restrictor ● ● ● ● = yes | … An additional suitability certificate is required with the door for fire and smoke protection doors. | … Can be retrofitted, not to fire and smoke protection doors | FSA = Hold-open device | FSA FL = Hold-open device with free swing Overview | For double leaf doors |  Integrated door closers OV E RV IE W TA B LE O F I N T EG R AT E D D O O R CLO SERS For double leaf doors Boxer ISM Boxer E-ISM Boxer ISM-EFS ● ● ● EN4 1100 FSA FSA FL Closing force acc. to EN 1154 2-4/3-6 2-4/3-6 4-6/3-6 (2-4) Door leaf width (max.) in mm 1100/1400 1100/1400 1400/1400 (1100) 130/180 130/180 180/180 (130) Approval for fire and smoke protection doors1 Barrier-free in accordance with DIN 18040 up to leaf width (max.) in mm Leaf weight (max.) in kg POSSIBLE APPLICATIONS Closer body integrated in the door leaf ● ● ● Guide rail integrated in the door frame ● ● ● 120° 120° 120° Opening angle (max.) FUNCTIONS Closing force, adjustable ● ● ● Back check, adjustable ● ● ● Latching action, adjustable ● ● ● Closing speed, adjustable ● ● ● Mechanical hold-open device² ● Electric hold-open device ● Electric hold-open device for free swing ● Mechanical closing sequence control, integrated ● ● ● Flexible opening restrictor ● ● ● ● = yes | … An additional suitability certificate is required with the door for fire and smoke protection doors. | … Can be retrofitted, not to fire and smoke protection doors | FSA = Hold-open device | FSA FL = Hold-open device with free swing … 6 … SW ING D O OR For single leaf doors Comfort with safety – that is what integrated door closers from GEZE offer. They close your swing doors gently and quietly, and brake the door's swing due to their back check function. You can always count on GEZE Boxer solutions for single leaf swing doors. You determine the closing speed. You can count on the highest level of safety with all integrated door closers. … Integrated door closers | For single leaf doors | Boxer Boxer Integrated door closer for single leaf doors up to 1400 mm leaf width ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Right and left single-action doors Single-action doors up to 1400 mm leaf width, for door weights up to 180 kg For door leaf thicknesses from 40 mm Integrated installation PR OD U CT F E AT U R ES Closing force of EN2-4 or EN3-6 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed Boxer | For single leaf doors |  Integrated door closers PR OD U CT S CA LE D R AW I N G 440 31 42 45 42 45 12 20,5 20,7 29,2 20 32 32 240 Closing force 2-4 440 31 40 51 54 51 54 12 20,5 20,7 29,2 20 40 249,8 Closing force 3-6 TEC HN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer Boxer 3-6 door closer PRODUCT FEATURES Closing force acc. to EN 1154 Leaf width recommended up to 2–4 2–4 3–6 1100 mm 1100 mm 1400 mm Recommended leaf weight of up to 130 kg 130 kg 180 kg Minimum leaf thickness 40 mm 40 mm 50 mm ● ● Identical design for DIN left and DIN right ● Statements of approval Length Door closer tested acc. to EN 1154 286 mm 286 mm 293 mm Overall depth 32 mm 32 mm 40 mm Height 45 mm 45 mm 54 mm FUNCTIONS Closing force adjustable Yes, with variable adjustment Closing speed adjustable ● Latching action adjustable Yes, via valve Back check integrated Yes, hydraulically adjustable Position of closing force adjustment top Safety valve to prevent intentional damage Valve control for regulating the latching action speed ● = yes | ○ = optional ● - ● - … Integrated door closers | For single leaf doors | Boxer TECHN ICAL DATA FO R G U I D E R A I L Guide rail Boxer 12 mm Guide rail Boxer … mm PRODUCT FEATURES Use on single / double-action door Single-action door Length 440 mm Overall depth 20 mm 31 mm Height 12 mm … mm FUNCTIONS Opening restrictor integrated - Holding open ○ ● = yes | ○ = optional INSTA LLATION D RAW I N G S B OX ER S I Z E 2-4 22 … 95 22 440 9,5 9,5 20,7 … 4,5 7,5 51 … 12 32,5 27 27 240 107,8 20 20 175 99 286 Installation on timber door | … = guide rail offset max. 10 mm 95 440 456 87 16,2 27 43 … 27 7,5 … 43 10 78,5 175 107,8 99 Installation on metal door | … = guide rail offset max. 10 mm 240 286 95 Boxer | For single leaf doors |  Integrated door closers B OX ER SI Z E … -6 95 30 440 9,5 9,5 4,5 60 7,5 12 20,7 … 4 30 … 25,5 25 35,5 25 175 103,2 249,8 94,5 293 Installation on timber door | … = guide rail offset max. 10 mm … 34 23,5 … 34 95 440 86,5 457,5 23,5 175 103,2 94,5 Installation on metal door | … = guide rail offset max. 10 mm 249,8 293 87 11 12 Integrated door closers | For single leaf doors | Boxer BOXE R – OR D E R I N FO R M AT I O N Designation Spindle extension Boxer 2-4 door closer closing force EN 2-4 with back check (without guide rail) … mm 099728 … mm 101759 Boxer 2-4 2V door closer closing force EN 2-4 with back check and independent latching action valve smooth latching function also possible, without guide rail) … mm 134448 … mm 134493 … mm 134494 Boxer 3-6 door closer closing force EN 3-6 with back check (without guide rail) … mm 099735 … mm 101761 … mm 101762 Boxer guide rail 12 mm with lever, overall height 12 mm Guide rail Boxer 12 mm with tapered lever, overall height 12 mm Boxer guide rail … mm with lever, overall height … mm Boxer guide rail … mm with lever and mechanical hold-open device, overall height … mm Version ID no. silver-coloured 129213 silver-coloured 184365 acc. to RAL1 135732 silver-coloured 112161 silver-coloured 095141 acc. to RAL1 135689 ACCESSORIES Mechanical hold-open device for standard/T-Stop/Boxer … mm guide rail, retention force adjustable, can be switched on and off, can be overridden 071924 Mechanical hold open unit for Boxer 12 mm guide rail, retention force adjustable, cannot be overridden 129145 Flexible opening restriction for lightweight doors for riveted guide rails, standard guide rail BG and Boxer guide rail … mm 069780 Flexible opening restriction for lightweight doors for Boxer guide rail 12 mm 129343 … surcharge for RAL special colours, see General Notes in the price list. Boxer | For single leaf doors |  Integrated door closers MST Medisch Spectrum Twente, Enschede, Benelux (photo: Erwin Kamphuis) 13 14 Integrated door closers | For single leaf doors | Boxer E Boxer E Integrated door closer for single leaf doors with a leaf width of up to 1400 mm with electric hold-open device ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Right and left single-action doors Single-action doors up to 1400 mm leaf width, for door weights up to 180 kg For door leaf thicknesses from 40 mm Integrated installation Hold-open systems with integrated hold-open function PR OD U CT F E AT U R ES Closing force of EN2-4 or EN3-6 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Electric hold-open device in the guide rail with hold-open area of 80°-120° Retention force of the hold-open function with variable adjustment Smoke switch control unit can be connected, with a signal that closes the door automatically in the event of a fire Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed Boxer E | For single leaf doors |  Integrated door closers PR OD U CT S CA LE D R AW I N G 42 83,5 30 440 32 240 Closing force 2-4 440 51 54 92,5 30 31 40 249,8 Closing force 3-6 TEC HN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer Boxer 3-6 door closer PRODUCT FEATURES Closing force acc. to EN 1154 Leaf width recommended up to 2–4 2–4 3–6 1100 mm 1100 mm 1400 mm Recommended leaf weight of up to 130 kg 130 kg 180 kg Minimum leaf thickness 40 mm 40 mm 50 mm Identical design for DIN left and DIN right ● Statements of approval Length Door closer tested acc. to EN 1154 286 mm 286 mm 293 mm Overall depth 32 mm 32 mm 40 mm Height 45 mm 45 mm 54 mm FUNCTIONS Closing force adjustable Yes, with variable adjustment Closing speed adjustable ● Latching action adjustable Yes, via valve Back check integrated Yes, hydraulically adjustable Position of closing force adjustment top Safety valve to prevent intentional damage Valve control for regulating the latching action speed ● = yes | ○ = optional ● - ● - 15 Integrated door closers | For single leaf doors | Boxer E TECHN ICAL DATA FO R G U I D E R A I L E guide rail Boxer PRODUCT FEATURES Use on single / double-action door Single-action door Supply voltage 24 V DC IP rating IP 43 Statements of approval Hold-open device tested acc. to EN 1155 Length 440 mm Overall depth 31 mm Height 30 mm FUNCTIONS Holding open Electrical Hold-open function can be switched on and off ● Hold-open function can be overridden ● ● = yes | ○ = optional INSTA LLATION D RAW I N G S B OX ER E SI Z E 2-4 95 22 440 9,5 9,5 4,5 51 7,5 … 30 … 27 27 32,5 107,8 20 98 240 175 99 286 Installation on timber door | … = guide rail offset max. 10 mm B OX ER E SI Z E … -6 … 95 27 440 9,5 9,5 54,5 25,5 16 175 103,2 94,5 Installation on metal door | … = guide rail offset max. 10 mm 249,8 293 Boxer E | For single leaf doors |  Integrated door closers BOX E R E – OR DE R I N FO R M AT I O N Designation Spindle extension Boxer 2-4 door closer Closing force EN 2-4 with back check (without guide rail) … mm 099728 … mm 101759 Boxer 2-4 2V door closer Closing force EN 2-4 with back check and independent latching action valve (smooth latching function also available, without guide rail) … mm 134448 … mm 134493 … mm 134494 Boxer 3-6 door closer Closing force EN 3-6 with back check (without guide rail) … mm 099735 … mm 101761 … mm 101762 E guide rail Boxer with lever and electric hold-open device Version ID no. silver-coloured 119640 acc. to RAL2 135775 ACCESSORIES 145311 Flexible opening restrictor for guide rail 1-leaf: TS 5000 E/R/RFS (door leaf installation), Boxer E; 2-leaf: all E/R/ISM variants TS 5000 and Boxer RSZ … smoke switch control unit Smoke switch control unit for all GEZE hold-open devices silver-coloured 181025 white RAL 9016 184195 stainless steel optic¹ 184196 acc. to RAL² 185231 195524 FA GC 170 wireless KIT Set consisting of: … piece GC 171 wireless module for the wireless extension of GEZE hold-open systems GC 171 wireless module for the wireless connection of wireless components (GC 172 wireless smoke detector; GC 173 wireless thermal detector; GC 175 wireless input module) on GEZE hold-open systems anthracite 163051 GC 172 wireless smoke detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195522 GC 173 wireless thermal detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195523 GC 175 wireless input module for wireless connection of manual trigger switches to the GEZE GC 171 wireless module, applicable for all GEZE hold-open systems black 163068 GC 152 smoke detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-7, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139850 acc. to RAL2 170523 GC 153 wireless thermal detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN54-5, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139881 acc. to RAL2 170524 Manual trigger switch Flush-mounted version for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring alpine white 116266 Manual trigger switch with glass pane and … interchangeable labels Flush-mounted version for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring alpine white 120880 Surface-mounted box, single suitable for the AS 500 switch programme … only for dry rooms | … surcharge for RAL special colours, see General Notes in the price list. 120503 17 18 Integrated door closers | For single leaf doors | Boxer P Boxer P Integrated door closer for single leaf double-action doors with a leaf width of up to 1100 mm ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Right and left double-action doors Double-action doors up to 1100 mm leaf width and 80 kg weight For door leaf thicknesses from 40 mm Integrated installation PR OD U CT F E AT U R ES Adjustable closing force of EN2-4 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed Boxer P | For single leaf doors |  Integrated door closers PR OD U CT S CA LE D R AW I N G 440 31 42 45 42 45 12 20,5 20,7 29,2 20 240 Boxer P TEC HN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer PRODUCT FEATURES Closing force acc. to EN 1154 2–4 Leaf width recommended up to 1100 mm Recommended leaf weight of up to 80 kg Minimum leaf thickness 40 mm Identical design for DIN left and DIN right ● Statements of approval Door closer tested acc. to EN 1154 Length 286 mm Width 32 mm Height 45 mm FUNCTIONS Closing force adjustable Yes, with variable adjustment Closing speed adjustable ● Latching action adjustable Yes, via valve Back check integrated Yes, hydraulically adjustable Position of closing force adjustment Top Safety valve to prevent intentional damage ● ● = yes | ○ = optional TEC HN ICAL DATA FO R G U I D E R A I L Guide rail Boxer 12 mm Guide rail Boxer … mm PRODUCT FEATURES Use on single / double-action door Double-action door Length 440 mm Width 20 mm 31 mm Height 12 mm … mm FUNCTIONS Opening restrictor integrated Holding open Optional Mechanical Hold-open function can be switched on and off - ● Hold-open function can be overridden - ● ● = yes | ○ = optional 19 Integrated door closers | For single leaf doors | Boxer P INSTA LLATION D RAW I N G S B OX ER P S I Z E 2-4 174 440 118 … 8,5 46 … 31 … 23 20,7 46,5 … 70 12 Ø 25 46,5 20 25 106,8 96 29 240 286 Installation on timber door BOXE R P– OR D E R I N FO R M AT I O N Designation Spindle extension Version ID no. Boxer 2-4 door closer Closing force EN 2-4 with back check (without guide rail) … mm 099728 … mm 101759 Boxer 2-4 2V door closer Closing force EN 2-4 with back check and independent latching action valve (smooth latching function also available, without guide rail) … mm 134448 … mm 134493 … mm 134494 Guide rail Boxer 12 mm with lever for double-action doors, overall height 12 mm (only Boxer 2-4) silver-coloured 129344 acc. to RAL1 135733 Guide rail Boxer … mm with lever for double-action doors with mechanical hold-open device, Overall height … mm (only Boxer 2-4) silver-coloured 104246 acc. to RAL1 135731 ACCESSORIES Mechanical hold-open function for standard / T-Stop / Boxer … mm guide rail, retention force adjustable, can be switched on and off, can be overridden 071924 Mechanical hold-open function for Boxer 12 mm guide rail, retention force adjustable, cannot be overridden 129145 Flexible opening restriction for lightweight doors for riveted guide rail, standard guide rail BG and Boxer … mm guide rail 069780 Flexible opening restriction for lightweight doors for Boxer guide rail 12 mm 129343 … surcharge for RAL special colours, see General Notes in the price list. Boxer P | For single leaf doors |  Integrated door closers Hotel, Berlin, Germany (photo: Stefan Dauth) 21 22 23 SW ING D O OR For single leaf doors with free swing function For added comfort and safety, the integrated door closer is available with electric free swing function. It can be used to open your single leaf swing door with minimal force. The comfort latching function that locks the door at the end of its free swing area adds an extra feature to the free swing door closer. The system also fulfils discerning design requirements: The door closer is recessed into the door leaf and frame to fit perfectly in your swing door system. 24 Integrated door closers | For single leaf doors with free swing function | Boxer EFS 4-6 Boxer EFS 4-6 Integrated door closer for single leaf doors up to 1400 mm leaf width with electric free swing function ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Right and left single-action doors Single-action doors up to 1400 mm leaf width and 180 kg leaf weight Integrated installation Hold-open systems with integrated hold-open function with free swing Barrier-free access in accordance with DIN 18040 PR OD U CT F E AT U R ES Closing force of EN 4-6 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Closing sequence control holds the active leaf in the waiting position until the passive leaf is closed Free swing function means comfortable use of the door with little effort Comfort hold-open function locks the door leaf at the end of the free swing area Smoke switch control unit can be connected, with a signal that closes the door automatically in the event of a fire Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed Boxer EFS 4-6 | For single leaf doors with free swing function |  Integrated door closers P l e a s e n o t e : According to the general DIBt official building approval for hold-open systems, the use of a manual trigger switch for free swing door closers is compulsory. PR OD U CT S CA LE D R AW I N G Boxer EFS TEC HN ICAL DATA FO R D O O R CLO SE R Boxer EFS 4-6 PRODUCT FEATURES Closing force acc. to EN 1154 Leaf width recommended up to 4-6 1400 mm Recommended leaf weight of up to 180 kg Minimum leaf thickness 50 mm Identical design for DIN left and DIN right Supply voltage IP rating Statements of approval ● 24 V DC IP43 Door closer tested acc. to EN 1154 Hold-open device tested acc. to EN 1155 Length 332 mm Overall depth 40 mm Height 54 mm FUNCTIONS Closing force adjustable ● Closing speed adjustable ● Latching action adjustable Yes, via valve Back check integrated Yes, mechanically in the guide rail Position of closing force adjustment electrical / for free swing function Safety valve to prevent intentional damage Hold-open function integrated ● = yes | ○ = optional ● electrical / for free swing function 25 Integrated door closers | For single leaf doors with free swing function | Boxer EFS 4-6 INSTA LLATION D RAW I N G S B OX ER EFS 31 40 Installation on timber door | … = guide rail offset max. 10 mm … Installation on metal door | … = guide rail offset max. 10 mm 54 … 51 26 Boxer EFS 4-6 | For single leaf doors with free swing function |  Integrated door closers BOX E R E FS – O R D E R I N FO R M AT I O N Designation Version ID no. Boxer EFS 4-6 Closing force EN 4-6, with electric free swing function incl. free swing lever with comfort hold-open function 153559 Guide rail Boxer EFS 12 mm Overall height 12 mm, for Boxer EFS 4-6 153560 Guide rail Boxer EFS … mm Overall height … mm, for Boxer EFS 4-6 153571 ACCESSORIES Spindle extension Boxer EFS 4-6 RSZ … smoke switch control unit Smoke switch control unit for all GEZE hold-open devices … mm 153573 … mm 153574 silver-coloured 181025 white RAL 9016 184195 stainless steel optic¹ 184196 acc. to RAL² 185231 195524 FA GC 170 wireless KIT Set consisting of: … piece GC 171 wireless module for the wireless extension of GEZE hold-open systems GC 171 wireless module for the wireless connection of wireless components (GC 172 wireless smoke detector; GC 173 wireless thermal detector; GC 175 wireless input module) on GEZE hold-open systems anthracite 163051 GC 172 wireless smoke detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195522 GC 173 wireless thermal detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195523 GC 175 wireless input module for wireless connection of manual trigger switches to the GEZE GC 171 wireless module, applicable for all GEZE hold-open systems black 163068 GC 152 smoke detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-7, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139850 acc. to RAL2 170523 GC 153 wireless thermal detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-5, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139881 acc. to RAL2 170524 AS 500 manual trigger switch for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring alpine white/red AS 500 manual trigger switch (with glass pane and … interchangeable labels) for the manual release of electrically controlled hold-open devices alpine white/red Surface-mounted box, single suitable for the AS 500 switch programme white … only for dry rooms | … surcharge for RAL special colours, see General Notes in the price list. 116266 120880 120503 27 28 29 SW ING D O OR For double leaf doors An integrated door closer with closing sequence control is used to close double leaf doors safely. It guarantees that the active leaf closes after the passive leaf. This ensures that nothing and no one can become trapped. GEZE Boxer solutions available for double leaf swing doors have been designed to optimally match your swing door, and can be individually adjusted. 30 Integrated door closers | For double leaf doors | Boxer ISM Boxer ISM Integrated door closer system for double leaf doors with closing sequence control ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Double leaf single-action doors Single-action doors up to 2800 mm hinge clearance, 1400 mm leaf width, for door widths up to 180 kg Minimum hinge clearance 1300 mm, minimum width of passive leaf 540 mm For door leaf thicknesses from 40 mm Integrated installation PR OD U CT F E AT U R ES System made of two Boxer door closers and an ISM guide rail Closing force of EN2-4 or EN3-6 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Closing sequence control holds the active leaf in the waiting position until the passive leaf is closed Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted Integrated back check, slows down doors that are thrown open forcefully All functions can be adjusted when installed S P ECI A L VER S I O NS: For doors with narrow hinge clearance from 1130 mm (opening angle max. 100°) For doors with small passive leaf from 420 mm (opening angle passive leaf max. 100°) Boxer ISM | For double leaf doors |  Integrated door closers PR OD U CT S CA LE D R AW I N G 484 614 31 30 38,5 45 Active leaf 240 42 240 Passive leaf 32 Boxer ISM, closing force 2-4 484 614 31 30 38,5 45 Active leaf 240 42 240 Passive leaf 32 Boxer ISM, closing force 3-6 435 614 31 240 42 Active leaf 32 Boxer ISM for small passive leaf, closing force 2-4 45 30 38,5 240 Passive leaf 31 Integrated door closers | For double leaf doors | Boxer ISM 435 614 31 240 30 38,5 240 Passive leaf 45 42 Active leaf 32 Boxer ISM for small passive leaf, closing force 3-6 435 614 31 240 30 38,5 240 Passive leaf 45 42 Active leaf 32 Boxer ISM for small hinge clearance, closing force 2-4 435 614 31 240 Active leaf 32 Boxer ISM for small hinge clearance, closing force 3-6 45 30 38,5 240 42 32 Passive leaf Boxer ISM | For double leaf doors |  Integrated door closers TEC HN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer Boxer 3-6 door closer PRODUCT FEATURES Closing force acc. to EN 1154 2–4 2–4 3–6 1100 mm 1100 mm 1400 mm Recommended leaf weight of up to 130 kg 130 kg 180 kg Minimum leaf thickness 40 mm 40 mm 50 mm ● ● ● Leaf width recommended up to Identical design for DIN left and DIN right Statements of approval Length Door closer tested in accordance with EN 1154 286 mm 286 mm 293 mm Overall depth 32 mm 32 mm 40 mm Height 45 mm 45 mm 54 mm FUNCTIONS Closing force adjustable Closing speed adjustable Yes, with variable adjustment ● ● Latching action adjustable Back check integrated Yes, hydraulically adjustable Position of closing force adjustment Safety valve to prevent wilful damage ● Yes, via valve top ● ● Valve control for regulating the latching action speed ● ● TEC HN ICAL DATA FO R G U I D E R A I L ISM guide rail Boxer ISM guide rail Boxer, small hinge clearance variant ISM guide rail Boxer, small passive leaf variant Minimum hinge clearance 1300 mm 1130 mm 1230 mm Minimum passive leaf width 540 mm 420 mm 420 mm PRODUCT FEATURES Statements of approval Closing sequence controller tested acc. to EN 1158 Overall depth 31 mm Height 30 mm FUNCTIONS Closing sequence control integrated ● ● ● Hold-open function integrated ○ ○ ○ ● = yes | ○ = optional 33 Fixed leaf – right leaf Smallest door width B = 1300 mm Largest door width B = 2800 mm GEZE Boxer size 3-6 Dimensions GEZE Boxer size 3-6 Dimensions GEZE Boxer size 2-4 Smallest door width B = 1300 mm Largest door width B = 2200 mm GEZE Boxer size 2-4 Dimensions GEZE Boxer size 2-4 GF = Moving leaf Door opening angle approx. 120° Minimum width of fixed leaf = 540 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, moving leaf GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf 24V cable (E-ISM) Channel cover, (wire cable/24V cable) Wire cable Frame machining, fixed leaf Door leaf machining, fixed leaf GEZE Boxer size 3-6 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Integrated door closers Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf 34 | For double leaf doors | Boxer ISM IN STALLATION D R AW I N G B OX E R I SM / E- I SM STAN DAR D I N TI M BER DO O R Smallest door width B = 1230 mm Largest door width B = 1940 mm GEZE Boxer size 3-6 Door leaf machining, moving leaf GEZE Boxer size 2-4 Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf Dimensions GEZE Boxer size 3-6 Dimensions GEZE Boxer size 2-4 Smallest door width B = 1230 mm Largest door width B = 1640 mm Channel cover, (wire cable/24V cable) Wire cable GEZE Boxer size 2-4 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Frame machining, fixed leaf Dimensions GEZE Boxer size 2-4 SF = Fixed leaf GF = Moving leaf TÖW = Door opening angle SF door opening angle approx. 120° GF door opening angle approx. 120° SF hold-open angle at approx. 80° - 90° TÖW GF hold-open angle at approx. 80° - 120° TÖW Width of fixed leaf = 420-540 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, fixed leaf GEZE Boxer size 3-6 Mirror imaged frame and door machining for left leaf Fixed leaf – right leaf 24V cable (E-ISM) Shown without cover Boxer ISM | For double leaf doors |  Integrated door closers IN STA LLATI O N D R AW I N G B OX E R I S M / E- I SM SM ALL PASSI VE LEAF I N TI M BER DO O R 35 Smallest door width B = 1130 mm Largest door width B = 1300 mm GEZE Boxer size 3-6 Door leaf machining, moving leaf GEZE Boxer size 2-4 Dimensions GEZE Boxer size 3-6 Channel cover, (wire cable/24V cable) Wire cable Dimensions GEZE Boxer size 2-4 24V cable (E-ISM) Shown without cover Smallest door width B = 1130 mm Largest door width B = 1300 mm GEZE Boxer size 2-4 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Fixed leaf – right leaf Dimensions GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf SF = Fixed leaf GF = Moving leaf TÖW = Door opening angle FL door opening angle approx. 120° FL hold-open angle at approx. 80° - 90° DOA Minimum width of fixed leaf = 420 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, fixed leaf GEZE Boxer size 3-6 Frame machining, fixed leaf Integrated door closers Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf 36 | For double leaf doors | Boxer ISM INSTA LLATION D R AW I N G B OX E R I SM / E- I SM SM ALL HI N G E CLEAR AN CE I N TI M BER DO O R Boxer ISM | For double leaf doors |  Integrated door closers BOX E R IS M– O R D E R I N FO R M AT I O N Designation Spindle extension Boxer 2-4 door closer Closing force EN 2-4 with back check (without guide rail) … mm Version 099728 ID no. … mm 101759 Boxer 2-4 2V door closer Closing force EN 2-4 with back check and independent latching action valve (smooth latching function also available, without guide rail) … mm 134448 … mm 134493 … mm 134494 Boxer 3-6 door closer Closing force EN 3-6 with back check (without guide rail) … mm 099735 … mm 101761 … mm 101762 ISM guide rail Boxer with integrated closing sequence control and levers silver-coloured 114141 ISM guide rail Boxer version, small hinge clearance especially for small hinge clearances from 1130 mm, with integrated closing sequence control and levers silver-coloured 120894 ISM guide rail Boxer version, small passive leaf especially for doors with small passive leaf from 420 mm, with integrated closing sequence control and levers silver-coloured 128597 ACCESSORIES GEZE flexible opening restrictor for guide rail 1-leaf: TS 5000 E/R/RFS (door leaf installation), Boxer E; 2-leaf: all E/R/ISM variants TS 5000 and Boxer CB flex carry bar for use on all 2-leaf rebated doors. Concealed length adjustment with variable adjustment up to 210 mm leaf protrusion, hinged mechanism not visible, profile can be shortened if necessary, with attachment material Mechanical hold-open function for ISM-guide rail, retention force adjustable, can be overridden … surcharge for RAL special colours, see General Notes in the price list. Only for dry rooms | … surcharge for RAL special colours, see General Notes in the price list. 145311 acc. to RAL1 153728 silver-coloured 153602 118437 37 38 Integrated door closers | For double leaf doors | Boxer E-ISM Boxer E-ISM Integrated door closer system for double leaf doors with closing sequence control and electric hold-open device ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Double leaf single-action doors Symmetrical and asymmetrical division of door possible Single-action doors up to 2800 mm hinge clearance, 1400 mm leaf width, for door widths up to 180 kg Minimum hinge clearance 1300 mm, minimum width of passive leaf 540 mm For door leaf thicknesses from 40 mm Integrated installation PR OD U CT F E AT U R ES System made of two Boxer door closers and an E- ISM guide rail Closing force of EN 2-4 or EN 3-6 with variable adjustment Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Closing sequence control holds the active leaf in the waiting position until the passive leaf is closed Electric hold-open device in the guide rail with hold-open area of 80°-120° Retention force of the hold-open function with variable adjustment Smoke switch control unit can be connected, with a signal that closes the door automatically in the event of a fire Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed S P ECI A L VERSI O N S: For doors with narrow hinge clearance from 1130 mm (opening angle max. 100°) For doors with small passive leaf from 420 mm (opening angle passive leaf max. 100°) Boxer E-ISM | For double leaf doors |  Integrated door closers PR OD U CT S CA LE D R AW I N G 484 614 31 30 42 Active leaf 38,5 240 Passive leaf 45 240 32 Boxer E-ISM, closing force 2-4 484 614 31 249,8 51 54 30 38,5 249,8 Active leaf Passive leaf 40 Boxer E-ISM, closing force 3-6 435 614 31 240 42 Active leaf 32 Boxer E-ISM for small passive leaf, closing force 2-4 45 30 38,5 240 Passive leaf 39 Integrated door closers | For double leaf doors | Boxer E-ISM 435 614 31 249,8 54 30 51 Active leaf 38,5 249,8 Passive leaf 40 Boxer E-ISM for small passive leaf, closing force 3-6 435 577 31 Passive leaf 45 42 Active leaf 38,5 240 30 240 32 Boxer E-ISM for small hinge clearance, closing force 2-4 435 577 31 249,8 30 38,5 249,8 Active leaf 51 54 40 40 Boxer E-ISM for small hinge clearance, closing force 3-6 Passive leaf Boxer E-ISM | For double leaf doors |  Integrated door closers TEC HN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer Boxer 3-6 door closer PRODUCT FEATURES Closing force acc. to EN 1154 2–4 2–4 3–6 1100 mm 1100 mm 1400 mm Recommended leaf weight of up to 130 kg 130 kg 180 kg Minimum leaf thickness 40 mm 40 mm 50 mm ● ● ● Leaf width recommended up to Identical design for DIN left and DIN right Statements of approval Length Door closer tested acc. to EN 1154 286 mm 286 mm 293 mm Overall depth 32 mm 32 mm 40 mm Height 45 mm 45 mm 54 mm FUNCTIONS Closing force adjustable Closing speed adjustable Yes, with variable adjustment ● ● Latching action adjustable Back check integrated Yes, hydraulically adjustable Position of closing force adjustment Safety valve to prevent intentional damage ● Yes, via valve top ● ● Valve control for regulating the latching action speed ● ● ● = yes | ○ = optional TEC HN ICAL DATA FO R G U I D E R A I L E-ISM guide rail Boxer E-ISM guide rail Boxer variant, E-ISM guide rail Boxer variant, small hinge clearance small passive leaf PRODUCT FEATURES Minimum hinge clearance 1300 mm 1130 mm 1230 mm Minimum passive leaf width 540 mm 420 mm 420 mm Supply voltage 24 V DC IP rating IP 43 Statements of approval Hold-open device tested acc. to EN 1155 Closing sequence controller tested acc. to EN 1158 Overall depth 31 mm Height 30 mm FUNCTIONS Closing sequence control integrated ● Hold-open function integrated ● ● electrical Hold-open function on active leaf / passive leaf ●/● Hold-open function can be switched on and off ● ● ● Hold-open function can be overridden ● ● ● ● = yes | ○ = optional 41 Fixed leaf – right leaf Smallest door width B = 1300 mm Largest door width B = 2800 mm GEZE Boxer size 3-6 Dimensions GEZE Boxer size 3-6 Dimensions GEZE Boxer size 2-4 Smallest door width B = 1300 mm Largest door width B = 2200 mm GEZE Boxer size 2-4 Dimensions GEZE Boxer size 2-4 GF = Moving leaf Door opening angle approx. 120° Minimum width of fixed leaf = 540 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, moving leaf GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf 24V cable (E-ISM) Channel cover, (wire cable/24V cable) Wire cable Frame machining, fixed leaf Door leaf machining, fixed leaf GEZE Boxer size 3-6 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Integrated door closers Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf 42 | For double leaf doors | Boxer E-ISM INSTA LLATION D R AW I N G B OX E R I S M / E- I SM STAN DAR D I N TI M BER DO O R Smallest door width B = 1230 mm Largest door width B = 1940 mm GEZE Boxer size 3-6 Door leaf machining, moving leaf GEZE Boxer size 2-4 Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf Dimensions GEZE Boxer size 3-6 Dimensions GEZE Boxer size 2-4 Smallest door width B = 1230 mm Largest door width B = 1640 mm Channel cover, (wire cable/24V cable) Wire cable GEZE Boxer size 2-4 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Frame machining, fixed leaf Dimensions GEZE Boxer size 2-4 SF = Fixed leaf GF = Moving leaf TÖW = Door opening angle SF door opening angle approx. 120° GF door opening angle approx. 120° SF hold-open angle at approx. 80° - 90° TÖW GF hold-open angle at approx. 80° - 120° TÖW Width of fixed leaf = 420-540 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, fixed leaf GEZE Boxer size 3-6 Mirror imaged frame and door machining for left leaf Fixed leaf – right leaf 24V cable (E-ISM) Shown without cover Boxer E-ISM | For double leaf doors |  Integrated door closers IN STA LLATI O N D R AW I N G B OX E R I SM / E- I SM SM ALL PASSI VE LEAF I N TI M BER DO O R 43 Smallest door width B = 1130 mm Largest door width B = 1300 mm GEZE Boxer size 3-6 Door leaf machining, moving leaf GEZE Boxer size 2-4 Dimensions GEZE Boxer size 3-6 Channel cover, (wire cable/24V cable) Wire cable Dimensions GEZE Boxer size 2-4 24V cable (E-ISM) Shown without cover Smallest door width B = 1130 mm Largest door width B = 1300 mm GEZE Boxer size 2-4 Mirror imaged frame and door machining for right leaf Moving leaf – left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = left leaf Concealed 24V power supply E-ISM guide rail / moving leaf = right leaf Fixed leaf – right leaf Dimensions GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf SF = Fixed leaf GF = Moving leaf TÖW = Door opening angle FL door opening angle approx. 120° FL hold-open angle at approx. 80° - 90° DOA Minimum width of fixed leaf = 420 mm plus space needed for fixed leaf lock Door leaf machining, fixed leaf GEZE Boxer size 2-4 Door leaf machining, fixed leaf GEZE Boxer size 3-6 Frame machining, fixed leaf Integrated door closers Door leaf machining, moving leaf GEZE Boxer size 3-6 Frame machining, moving leaf 44 | For double leaf doors | Boxer E-ISM IN STALLATION D R AW I N G B OX E R I SM / E- I SM SM ALL HI N G E CLEARAN CE I N TI M BER DO O R Boxer E-ISM | For double leaf doors |  Integrated door closers BOX E R E-IS M– O R D E R I N FO R M AT I O N Designation Spindle extension Boxer 2-4 door closer Closing force EN 2-4 with back check (without guide rail) … mm 099728 … mm 101759 Boxer 2-4 2V door closer Closing force EN 2-4 with back check and independent latching action valve (smooth latching function also available, without guide rail) … mm 134448 … mm 134493 … mm 134494 … mm 099735 … mm 101761 … mm 101762 Boxer 3-6 door closer Closing force EN 3-6 with back check (without guide rail) Version ID no. E-ISM guide rail Boxer With integrated closing sequence control, electric hold-open device on both leaves and levers silver-coloured 114142 E-ISM guide rail Boxer variant, small hinge clearance especially for small hinge clearances from 1130 mm, with integrated closing sequence control, electric hold-open device on both leaves and levers silver-coloured 120895 E-ISM guide rail Boxer variant, small passive leaf especially for doors with small passive leaf from 420 mm, with integrated closing sequence control, electric hold-open device on both leaves and levers silver-coloured 128598 ACCESSORIES Flexible opening restrictor for guide rail 1-leaf: TS 5000 E/R/RFS (door leaf installation), Boxer E; 2-leaf: all E/R/ISM variants TS 5000 and Boxer CB flex carry bar for use on all 2-leaf rebated doors. Concealed length adjustment with variable adjustment up to 210 mm leaf protrusion, hinged mechanism not visible, profile can be shortened if necessary, with attachment material RSZ … smoke switch control unit Smoke switch control unit for all GEZE hold-open devices 145311 acc. to RAL² 153728 silver-coloured 153602 silver-coloured 181025 white RAL 9016 184195 stainless steel optic¹ 184196 acc. to RAL² 185231 195524 FA GC 170 wireless KIT Set consisting of: … piece GC 171 wireless module for the wireless extension of GEZE holdopen systems GC 171 wireless module for the wireless connection of wireless components (GC 172 wireless smoke detector; GC 173 wireless thermal detector; GC 175 wireless input module) on GEZE hold-open systems anthracite 163051 GC 172 wireless smoke detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195522 GC 173 wireless thermal detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195523 GC 175 wireless input module for wireless connection of manual trigger switches to the GEZE GC 171 wireless module, applicable for all GEZE hold-open systems black 163068 GC 152 smoke detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-7, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139850 acc. to RAL2 170523 white 139881 acc. to RAL2 170524 alpine white 116266 GC 153 wireless thermal detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-5, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 Manual trigger switch Flush-mounted version for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring 120503 Surface-mounted box, single suitable for the AS 500 switch programme Manual trigger switch with glass pane and … interchangeable labels Flush-mounted version for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring … Only for dry rooms | … Surcharge for RAL special colours, see General Notes in the price list. alpine white 120880 45 46 47 SW ING D O OR For double leaf doors with free swing function For added comfort and safety, the integrated door closer is available with electric free swing function. It can be used to open your double leaf swing door with minimal force. The comfort latching function that locks the door at the end of its free swing area adds an extra feature to the free swing door closer. The system also fulfils discerning design requirements: The door closer is recessed into the door leaf and frame to fit perfectly in your swing door system. 48 Integrated door closers | For double leaf doors with free swing function | Boxer ISM-EFS Boxer ISM-EFS Integrated door closer system for double leaf doors with closing sequence control and electric free swing function ARE AS OF APP L I CAT I O N Fire and smoke protection doors, proof of suitability for the door required Double leaf single-action doors Symmetrical and asymmetrical division of door possible Single-action doors up to 2800 mm hinge clearance, 1400 mm leaf width, for door widths up to 180 kg Minimum hinge clearance 1300 mm, minimum width of passive leaf 540 mm For door leaf thicknesses from 50 mm Integrated installation Hold-open systems with integrated hold-open function with free swing Barrier-free access in accordance with DIN 18040 PR OD U CT F E AT U R ES System consisting of two door closers Boxer EFS- 4-6 and Boxer 2-4 or 3-6 with ISM guide rail Closing force of EN 4-6 with variable adjustment on the active leaf, EN 3-6 or EN 2-4 on the passive leaf Can be used for right and left hand doors without conversion Door closer is embedded in door leaf and frame and fulfils maximum design demands Closing sequence control holds the active leaf in the waiting position until the passive leaf is closed Free swing function means comfortable use of the door with little effort Comfort hold-open function locks the door leaf at the end of the free swing area Smoke switch control unit can be connected, with a signal that closes the door automatically in the event of a fire Integrated back check, slows down doors that are thrown open forcefully Hydraulic latching action which accelerates the door shortly before the closed position Closing speed can be individually adjusted All functions can be adjusted when installed S P ECI A L VER S I O NS: For doors with small passive leaf from 420 mm (opening angle passive leaf max. 100°) Boxer ISM-EFS | For double leaf doors with free swing function |  Integrated door closers PR OD U CT S CA LE D R AW I N G 614 … 484 … (240) Active leaf Passive leaf Boxer ISM-EFS 614 … Active leaf Boxer ISM-EFS for small passive leaf 435 … (240) Passive leaf 49 50 Integrated door closers | For double leaf doors with free swing function | Boxer ISM-EFS TECHN ICAL DATA FO R D O O R CLO SE R Boxer 2-4 door closer Boxer 2-4 2V door closer Boxer 3-6 door closer 2–4 2–4 3–6 Boxer EFS 4-6 PRODUCT FEATURES Closing force acc. to EN 1154 Leaf width recommended up to 1100 mm Recommended leaf weight of up to Minimum leaf thickness Identical design for DIN left and DIN right 4–6 1400 mm 130 kg 180 kg 180 kg 40 mm 40 mm 50 mm 50 mm ● ● ● ● Supply voltage 24 V DC IP rating Statements of approval Length IP 43 Door closer tested acc. to EN 1154 Door closer tested acc. to EN 1154 Door closer tested acc. to EN 1154 Door closer tested acc. to EN 1154 Hold-open device tested acc. to EN 1155 286 mm 286 mm 293 mm 332 mm Overall depth 32 mm 32 mm 40 mm 40 mm Height 45 mm 45 mm 54 mm 54 mm Closing force adjustable Yes, with variable adjustment Yes, with variable adjustment Yes, with variable adjustment Yes, with variable adjustment Closing speed adjustable ● ● ● ● Yes, hydraulically adjustable Yes, hydraulically adjustable Yes, hydraulically adjustable Yes, mechanically in the guide rail ● ● ● ● FUNCTIONS Latching action adjustable Back check integrated Yes, via valve Position of closing force adjustment Safety valve to prevent intentional damage Top Valve control for regulating the latching action speed ● Hold-open function integrated electrically, for free swing function ● = yes | ○ = optional TECHN ICAL DATA FO R G U I D E R A I L ISM guide rail Boxer ISM guide rail Boxer Small passive leaf variant Minimum hinge clearance 1300 mm 1230 mm Minimum passive leaf width 540 mm 420 mm PRODUCT FEATURES Statements of approval Closing sequence controller tested acc. to EN 1158 Overall depth 31 mm Height 30 mm FUNCTIONS Closing sequence control integrated ● = yes | ○ = optional ● ● Smallest door width B = 1335 mm Largest door width B = 2800 mm GEZE Boxer size 3-6 + EFS 4-6 Door leaf machining, active leaf GEZE Boxer EFS 4-6 Alternative positions Connecting terminal 24V DC Frame machining, active leaf Dimensions GEZE Boxer size 3-6 + EFS 4-6 Channel cover, (wire cable/24V cable) Dimensions GEZE Boxer size 2-4 Smallest door width B = 1335 mm Largest door width B = 2500 mm GEZE Boxer size 2-4 + EFS 4-6 Mirror imaged frame and door machining for right leaf Active leaf – left leaf Wire cable Dimensions GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf Passive leaf – right leaf GF = Active leaf SF = Passive leaf Door opening angle approx. 110° Minimum width of passive leaf = 540 mm plus space needed for passive leaf lock Door leaf machining, passive leaf GEZE Boxer 2-4 Door leaf machining, passive leaf GEZE Boxer 3-6 Frame machining, passive leaf Boxer ISM-EFS | For double leaf doors with free swing function |  Integrated door closers IN STA LLATION D R AW I N G B OX E R I S M - EFS STAN DAR D I N TI M BER DO O R 51 Alternative positions Connecting terminal 24V DC Smallest door width B = 1230 mm Largest door width B = 2800 mm GEZE Boxer size 3-6 + EFS 4-6 Dimensions GEZE Boxer size 3-6 + EFS 4-6 Connecting terminal Dimensions GEZE Boxer size 2-4 Smallest door width B = 1230 mm Largest door width B = 2500 mm GEZE Boxer size 2-4 + EFS 4-6 Mirror imaged frame and door machining for right leaf Active leaf – left leaf Channel cover, (wire cable) Wire cable Dimensions GEZE Boxer size 2-4 Mirror imaged frame and door machining for left leaf Passive leaf – right leaf GF = Active leaf SF = Passive leaf TÖW = Door opening angle Door opening angle GF approx. 100° Door opening angle SF approx. 110° Minimum width of passive leaf = 420-540 mm plus space needed for passive leaf lock Door leaf machining, passive leaf GEZE Boxer 2-4 Door leaf machining, passive leaf GEZE Boxer 3-6 Frame machining, passive leaf Integrated door closers Door leaf machining, active leaf GEZE Boxer EFS 4-6 Frame machining, active leaf 52 | For double leaf doors with free swing function | Boxer ISM-EFS INSTA LLATION D RAW I N G B OX E R I SM - E FS SM ALL PASSI VE LEAF I N TI M BER DO O R Boxer ISM-EFS | For double leaf doors with free swing function |  Integrated door closers BOX E R IS M-E FS– O R D E R I N FO R M AT I O N Designation Spindle extension Version ID no. Boxer EFS 4-6 Closing force EN 4-6, with electric free swing function incl. free swing lever with comfort lock function … mm 153559 Spindle extension Boxer EFS 4-6 … mm 153573 … mm 153574 Boxer 2-4 door closer Closing force EN 2-4 with back check (without guide rail) … mm 099728 … mm 101759 Boxer 2-4 2V door closer Closing force EN 2-4 with back check and independent latching action valve (smooth latching function also available, without guide rail) … mm 134448 … mm 134493 … mm 134494 Boxer 3-6 door closer Closing force EN 3-6 with back check (without guide rail) … mm 099735 … mm 101761 … mm 101762 ISM guide rail Boxer with integrated closing sequence control and levers silver-coloured 114141 ISM guide rail Boxer small passive leaf variant especially for doors with small passive leaf from 420 mm, with integrated closing sequence control and levers silver-coloured 128597 ACCESSORIES Flexible opening restrictor for guide rail 1-leaf: TS 5000 E/R/RFS (door leaf installation), Boxer E; 2-leaf: all E/R/ISM variants TS 5000 and Boxer 145311 CB flex carry bar for use on all 2-leaf rebated doors. Concealed length adjustment with variable adjustment up to 210 mm leaf protrusion, hinged mechanism not visible, profile can be shortened if necessary, with attachment material acc. to RAL² 153728 silver-coloured 153602 RSZ … smoke switch control unit Smoke switch control unit for all GEZE hold-open devices silver-coloured 181025 white RAL 9016 184195 stainless steel optic¹ 184196 acc. to RAL² 185231 195524 FA GC 170 wireless KIT Set consisting of: … piece GC 171 wireless module for the wireless extension of GEZE holdopen systems GC 171 wireless module for the wireless connection of wireless components (GC 172 wireless smoke detector; GC 173 wireless thermal detector; GC 175 wireless input module) on GEZE hold-open systems anthracite 163051 GC 172 wireless smoke detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195522 GC 173 wireless thermal detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195523 GC 175 wireless input module for wireless connection of manual trigger switches to the GEZE GC 171 wireless module, applicable for all GEZE hold-open systems black 163068 GC 152 smoke detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-7, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139850 GC 153 wireless thermal detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-5, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white Manual trigger switch Flush-mounted version for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring alpine white according to RAL² 170523 according to RAL² 170524 Replacement glass pane for manual trigger switch 120880 and 120881 … Only for dry rooms | … Surcharge for RAL special colours, see General Notes in the price list. 116266 120503 Surface-mounted box, single suitable for the AS 500 switch programme Manual trigger switch with glass pane and … interchangeable labels Flush-mounted installation for the manual release of electrically controlled hold-open devices 139881 alpine white 120880 10994 53 54 55 SW ING D O O R Boxer pivot bearing Integrated pivot bearing for opening restriction or hold-open function for doors without a door closer 56 Integrated door closers | Boxer pivot bearing Boxer pivot bearing Integrated pivot bearing for opening restriction or hold-open function for doors without a door closer ARE AS OF APP L I CAT I O N Right and left single- and double-action doors Opening restriction for single- or double-action doors without door closer Door systems without smoke and fire protection needs For combining an automatic swing door drive with a Boxer on double leaf door systems PR OD U CT F E AT U R ES Holds doors open without door closer, not self-locking The door opening angle is limited and a door stopper is usually no longer required Doing without door stoppers enhances the appearance of the door area, stumbling hazards and dirty corners disappear Can be used for right and left hand doors without conversion Crushing between door leaf and floor mounted door stopper is avoided Boxer pivot bearing |  Integrated door closers PR OD U CT S CA LE D R AW I N G Boxer pivot bearing IN STA LLATION I N FO R M AT I O N Pivot bearing with short cover plate Pivot bearing with long cover plate 57 58 Integrated door closers | Boxer pivot bearing BOXE R P IVOT B E A R I N G - O R D E R I N FO R M ATI O N Designation Spindle extension Boxer pivot bearing Integrated pivot bearing for opening restriction or holding open of doors without door closer, for use with all Boxer guide rails 0, 2, 4, 6, … mm Version ID no. 156278 Boxer guide rail 12 mm with lever, overall height 12 mm silver-coloured 129213 according to RAL1 135732 Boxer guide rail 12 mm with lever for double-action doors, overall height 12 mm (only Boxer 2-4) silver-coloured 129344 according to RAL1 135733 Guide rail Boxer 12 mm with tapered lever, overall height 12 mm silver-coloured 184365 acc. to RAL1 135732 Boxer guide rail … mm with lever, overall height … mm silver-coloured 112161 Boxer guide rail … mm with lever and mechanical hold-open device, overall height … mm silver-coloured 95141 according to RAL1 135689 Boxer guide rail … mm with lever for double-action doors and mechanical hold-open device, overall height … mm (only Boxer 2-4) silver-coloured 104246 according to RAL1 135731 ACCESSORIES Flexible opening restriction for lightweight doors for Boxer guide rail 12 mm 129343 Flexible opening restriction for lightweight doors for riveted guide rail, standard guide rail BG, standard guide rail and Boxer … mm guide rail 069780 Mechanical hold-open function for Boxer 12 mm guide rail, retention force adjustable, cannot be overridden 129145 Mechanical hold-open function for standard / T-Stop / Boxer … mm guide rail, retention force adjustable, can be switched on and off, can be overridden 071924 … Surcharge for RAL special colours, see General Notes in the price list. Boxer pivot bearing |  Integrated door closers Vitra Haus, Weil am Rhein, Germany (photo: Oliver Look) 59 60 61 SW ING D O OR Accessories To make your hold-open devices even safer in an emergency, we have a wide range of accessories in our product range. For example, you can opt for a GEZE smoke switch control unit. Manual or wireless – we have numerous versions on offer for you. We are more than happy to answer any questions you may have about your safe door. 62 INTEGRATED DOOR CLOSERS | Accessories | RSZ … SMOKE SWITCH CONTROL UNIT RSZ … smoke switch control unit Extendable smoke switch control unit for all GEZE hold-open devices ARE AS OF APP L I CAT I O N Approved for all GEZE hold-open devices for the early detection of fire and smoke Difficult lintel situations, for example with too little space above the smoke chamber Installation above the active leaf on the vertical wall Installation possible with surface-mounted line-feed PR OD U CT F E AT U R ES Telescopic function for bridging overhangs of up to 30 mm Connection to 230 V power supply and 24 V DC supply of the hold-open device Power supply of the hold-open system is interrupted in the case of an alarm and the doors close Integrated smoke switch with automatic adaptation of the alarm threshold Compensates for light contamination of the smoke chamber and thus increases the service life Visual display of the current control panel status Additional smoke switches can be connected Surface-mounted line-feed possible VIDEO RSZ … SMOKE SWITCH CONTROL UNIT | Accessories | INTEGRATED DOOR CLOSERS PR OD U CT S CA LE D R AW I N G 347 293 27 124 33 30 14 55 … 3 … 4 … = threaded hole M5 | … = opening for additional connections | … = power supply (230 V) | … = threaded hole M5 O R D E R IN FOR M AT I O N Designation Version ID no. RSZ … smoke switch control unit Smoke switch control unit for all GEZE hold-open devices silver-coloured 181025 white RAL 9016 184195 stainless steel optic¹ 184196 acc. to RAL² 185231 ACCESSORIES 195524 FA GC 170 wireless KIT Set consisting of: … piece GC 171 wireless module for the wireless extension of GEZE hold-open systems GC 171 wireless module for the wireless connection of wireless components (GC 172 wireless smoke detector; GC 173 wireless thermal detector; GC 175 wireless input module) on GEZE hold-open systems anthracite 163051 GC 172 wireless smoke detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195522 GC 173 wireless thermal detector for the wireless connection to GEZE hold-open systems, battery-operated with … years battery lifetime, with base, tested in accordance with EN 54-7 and EN 54-25, general construction technique permit for use with all GEZE hold-open systems white RAL 9016 195523 GC 175 wireless input module for wireless connection of manual trigger switches to the GEZE GC 171 wireless module, applicable for all GEZE hold-open systems black 163068 GC 152 smoke detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN 54-7, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139850 according to RAL² 170523 GC 153 wireless thermal detector Complete with base, 24 V DC, 20 mA, tested in accordance with EN54-5, with general official building approval for use with all GEZE hold-open systems, integrated line monitoring, conform with DIN EN 14637 white 139881 according to RAL² 170524 Manual trigger switch for the manual release of electrically controlled hold-open devices including terminating resistor for line monitoring alpine white/red 116266 Surface-mounted box, single suitable for the AS 500 switch programme Manual trigger switch with glass pane and … interchangeable labels for the manual release of electrically controlled hold-open devices … Only for dry rooms | … Surcharge for RAL special colours, see General Notes in the price list. 120503 alpine white/red 120880 63 64 65 SW ING D O OR Further information Product information for door closers 66 Integrated door closers | Further information | Product information for door closers Product information for door closers P R O DU CT I N FO R M ATION FOR DOOR CLOSERS Due to the liability the manufacturer has for its products under the German product liability law (§ … Prod-HaftG), the following information regarding door closers for swing doors must be observed. Failure to comply releases the manufacturer from his statutory liability. 1) PRODUCT INFORMATION AND USE AS INTENDED Within this context, door closers are to be defined as products for closing swing doors after they have been opened manually. The closing action is dampened using a hydraulically adjustable feature. The level of closing force required for specific leaf widths is defined in EN 1154. In the case of non-standard applications, the details provided by the manufacturer are to be regarded as definitive. Door closers are used on installed swing doors made from metal, timber or plastic and combinations thereof. When used on smoke and fire protection doors or other standardised self-locking doors, they are subject to strict requirements in terms of the type of installation and their position. Any deviation from these requirements constitutes improper use. Proper use of door closers (use as intended) relies on doors being installed perpendicular and their being able to move smoothly; it is also dependent on the door closers being properly secured. The products must be installed and adjusted professionally in accordance with the manufacturer’s specifications. Where local conditions are particularly unfavourable (wind), door closers with higher torques must be used. It is particularly important to use door closers with a back check function on swing doors that are exposed to wind when opening outwards. The back check function helps protect people, door elements, nearby walls and objects, without restricting the door opening angle. If the structural conditions of the door are such that there is a risk of the door leaf hitting the frame in the vicinity of the door’s axis of rotation, a buffer must be installed to limit the door’s maximum opening angle. If swing doors are to be fixed in the open position, this may only be achieved using special additional fittings or integrated constructional elements. When used on smoke and fire protection doors, the devices must be officially approved by Deutsches Institut für Bautechnik (German Centre of Competence for Construction) (door suitability certificates must be heeded). Door closers are not suitable for installation on swing doors in the case of exposed exterior installation or for installation in environments where the air contains aggressive, corrosive substances or in extremely high or low temperatures. Following installation, enclosures for floor springs must be protected against soiling. If floor springs are exposed to penetrating water such as wet rooms or exterior doors with no protection from the rain, the area between the cement box and the floor spring cover must be sealed with a suitable sealing compound. Compliance with mandatory statutory provisions must be ensured, where applicable, before door closers (including any additional devices) are installed and commissioned. 2) MISUSE Misuse (i.e. improper use of door closer products for swing doors) includes, in particular: the presence of obstacles in the closing area, scraping doors, sticking seals, wooden wedges, etc. that hinder the door’s closing action, if incorrect or improper mounting and/or adjustment occurs, if reaching into the area between the door frame and leaf (risk of injury), if the warranted properties are likely to trigger proper functioning, e.g. in case of storms or unusual levels of overpressure or underpressure acting on the door, if door closers are used for any purpose other than closing doors, if the selected closing force does not tally with the manufacturer's recommendations. 3) PRODUCT PERFORMANCE Where catalogues, brochures, manuals, etc. do not contain specific details of product performance, special requirements must be discussed and agreed with the manufacturer. The EN 1154 standards serve as a guideline. These standards stipulate the vast majority of basic and additional requirements. Amongst other things, the usability of door closers depends on how often they are operated, how they are operated, environmental influences and how they are cared for. Door closers must be replaced as soon as the door's closing action can no longer be guaranteed to be fault-free and reliable. Product information for door closers | Further information |  Integrated door closers 4) PRODUCT MAINTENANCE 5) DUTIES TO INFORM AND INSTRUCT Safety-related components of door closers must be checked regularly for tightness and signs of wear (depending on what the requirements are). Fixing screws must be re-tightened and defective components replaced. In addition, the following maintenance work must be carried out at least once a year (depending on the swing door type and extent of use). The following resources are available to help planners, specialist suppliers, installation companies, builders and users fulfil their duties of information and instruction: Grease all moving parts on the link arm. In the case of door closers with special functions (hold-open devices and hold-open systems), ensure compliance with statutory inspections, monitoring requirements and suggested maintenance intervals. Check the door closer settings e.g. the closing speed. Check that the door is able to move easily. Do not use any cleaning agents that contain corrosive or damaging ingredients. Andels Hotel, Berlin, Germany (photo: Stefan Dauth) Catalogues, brochures, leaflets, Tender texts and bidding documents, Attachment instructions, installation drawings, operating instructions, standards Advice from field staff. To ensure correct use of door closers on swing doors, guarantee their function and make sure they are maintained and cared for appropriately: Architects and planners are advised to order and observe the necessary product information, Specialist suppliers are advised to observe the product information and advice in the price lists and, in particular, to order all relevant instructions, which are to be passed on to the installation engineer, fabrication companies are advised to observe all the product, information and to pass it on to the client and user. 67 We are GEZE. For liveable buildings GEZE stands for innovation, high quality and comprehensive support of building technologies. From the initial idea, planning and operational implementation with standard products to customised system solutions and individual service and maintenance plans. We offer an extensive product range of door, window and safety technology products and are a major driving force behind the digital networking of building automation. GEZE GmbH Reinhold-Vöster-Strasse 21 – 29 71229 Leonberg Germany Telephone: +49 7152 203 … Fax: +49 7152 203 310 E-Mail: info.de@geze.com www.geze.com 2023_01 ID no. 091609 EN Subject to change without notice

PDF | 4 MB